In Vivo 3D Muscle Architecture Quantification Based on 3D Freehand Ultrasound and Magnetic Resonance Imaging

Abstract
Muscle architecture parameters, such as the fascicle length, pennation angle, and volume, are important muscle morphology characteristics. Accurate in vivo quantification of these parameters allows to detect changes due to pathologies, interventions, and rehabilitation trainings, which ultimately impact on muscles’ force-producing capacity. In this study, we compared three-dimensional (3D) muscle architecture parameters of the tibialis anterior and gastrocnemius medialis, which were quantified by 3D freehand ultrasound (3DfUS) and a magnetic resonance imaging (MRI) technique, diffusion tensor imaging (DTI), respectively. Sixteen able-bodied subjects were recruited where seven of them received both 3DfUS and MRI measurement, while the rest underwent 3DfUS measurements twice. Good to excellent intra-rater reliability and inter-session repeatability were found in 3DfUS measurements (intra-class correlation coefficient > 0.81). Overall, the two imaging modalities yielded consistent measurements of the fascicle length, pennation angle, and volume with mean differences smaller than 2.9 mm, 1.8°, and 5.7 cm3, respectively. The only significant difference was found in the pennation angle of the tibialis anterior, although the discrepancy was small. Our study demonstrated, for the first time, that 3DfUS measurement had high reliability and repeatability for measurement of muscle architecture in vivo and could be regarded as an alternative to MRI for 3D evaluation of muscle morphology.
Main Authors
Format
Articles Research article
Published
2023
Series
Subjects
Publication in research information system
Publisher
Elsevier
The permanent address of the publication
https://urn.fi/URN:NBN:fi:jyu-202304062420Käytä tätä linkitykseen.
Review status
Peer reviewed
ISSN
0021-9290
DOI
https://doi.org/10.1016/j.jbiomech.2023.111567
Language
English
Published in
Journal of Biomechanics
Citation
  • Wang, Z., Destro, A., Petersson, S., Cenni, F., & Wang, R. (2023). In Vivo 3D Muscle Architecture Quantification Based on 3D Freehand Ultrasound and Magnetic Resonance Imaging. Journal of Biomechanics, 152, Article 111567. https://doi.org/10.1016/j.jbiomech.2023.111567
License
CC BY 4.0Open Access
Funder(s)
European Commission
Funding program(s)
MSCA Individual Fellowship (IF)
MSCA Individual Fellowship (IF)
European Commission
Additional information about funding
Zhongzheng Wang thanks the financial support from Chinese Scholarship Council and Promobilia Foundation (Ref. 19088 & Ref. 21033). Francesco Cenni is funded by the European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No 101028724.
Copyright© 2023 the Authors

Share