Diagnostics of highly charged plasmas with multicomponent 1+ ion injection
Luntinen, M., Toivanen, V., Koivisto, H., Angot, J., Thuillier, T., Tarvainen, O., & Castro, G. (2022). Diagnostics of highly charged plasmas with multicomponent 1+ ion injection. Physical Review E, 106(5), Article 055208. https://doi.org/10.1103/PhysRevE.106.055208
Julkaistu sarjassa
Physical Review ETekijät
Päivämäärä
2022Tekijänoikeudet
©2022 American Physical Society
We establish multicomponent 1+ injection into a charge breeder electron cyclotron resonance ion source and an associated computational procedure as a noninvasive probe of the electron density ne, average electron energy ⟨Ee⟩, and the characteristic times of ionization, charge exchange, and ion confinement of stochastically heated, highly charged plasma. Multicomponent injection allows refining the ne, ⟨Ee⟩ ranges, reducing experimental uncertainty. Na/K injection is presented as a demonstration. The ⟨Ee⟩ and ne of a hydrogen discharge are found to be 600+600−300eV and 8+8−3×1011cm−3, respectively. The ionization, charge exchange, and confinement times of high charge state alkali ions are on the order of 1 ms–10 ms.
Julkaisija
American Physical Society (APS)ISSN Hae Julkaisufoorumista
2470-0045Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/164832520
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Rahoittaja(t)
Suomen AkatemiaRahoitusohjelmat(t)
Akatemiahanke, SALisätietoja rahoituksesta
We acknowledge grants of computer capacity from the Finnish Grid and Cloud Infrastructure [39] and support of the Academy of Finland Project funding (Grant No. 315855).Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
The effects of electron energy distribution and ionization cross section uncertainty on charge breeder ion source diagnostics with pulsed 1+ injection
Luntinen, M.; Angot, J.; Koivisto, H.; Tarvainen, O.; Thuillier, T.; Toivanen, V. (AIP Publishing, 2023)The consecutive transients (CT) method is a plasma diagnostic technique of charge breeder electron cyclotron resonance ion source plasmas. It is based on the short-pulse injection of singly charged ions and the measurement ... -
VUV-diagnostics of low temperature hydrogen plasmas
Komppula, Jani (University of Jyväskylä, 2015) -
Characteristic Kα emission of electron cyclotron resonance ion source plasmas
Sakieldien, Moenir (University of Jyväskylä, 2018)This thesis presents the results of an investigation of the volumetric Kα emission rate/inner shell ionization rate from an Electron Cyclotron Resonance Ion Source (ECRIS) plasma tuned predominantly for high charge state ... -
Plasma diagnostic tools for ECR ion sources : What can we learn from these experiments for the next generation sources
Tarvainen, O.; Kalvas, T.; Koivisto, H.; Kronholm, R.; Marttinen, M.; Sakildien, M.; Toivanen, V.; Izotov, I.; Skalyga, V.; Angot, J. (American Institute of Physics, 2019)The order-of-magnitude performance leaps of ECR ion sources over the past decades result from improvements to the magnetic plasma confinement, increases in the microwave heating frequency, and techniques to stabilize the ... -
Time resolved measurements of hydrogen ion energy distributions in a pulsed 2.45 GHz microwave plasma
Megía-Macías, A.; Cortázar, O. D.; Tarvainen, Olli; Koivisto, Hannu (AIP Publishing LLC, 2017)A plasma diagnostic study of the Ion Energy Distribution Functions (IEDFs) of H+, H+2H2+, and H+3H3+ ions in a 2.45 GHz hydrogen plasma reactor called TIPS is presented. The measurements are conducted by using a Plasma Ion ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.