Quantification of cortical proprioceptive processing through a wireless and miniaturized EEG amplifier
Giangrande, A., Cerone, G. L., Gazzoni, M., Botter, A., & Piitulainen, H. (2022). Quantification of cortical proprioceptive processing through a wireless and miniaturized EEG amplifier. In EMBC 2022 : 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (pp. 4797-4800). IEEE. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/EMBC48229.2022.9871637
Julkaistu sarjassa
Annual International Conference of the IEEE Engineering in Medicine and Biology SocietyPäivämäärä
2022Tekijänoikeudet
© 2022, IEEE
Corticokinematic coherence (CKC) is computed between limb kinematics and cortical activity (e.g. MEG, EEG), and it can be used to detect, quantify and localize the cortical processing of proprioceptive afference arising from the body. EEG-based studies on CKC have been limited to lab environments due to bulky, non-portable instrumentations. We recently proposed a wireless and miniaturized EEG acquisition system aimed at enabling EEG studies outside the laboratory. The purpose of this work is to compare the EEG-based CKC values obtained with this device with a conventional wired-EEG acquisition system to validate its use in the quantification of cortical proprioceptive processing. Eleven healthy right-handed participants were recruited (six males, four females, age range: 24–40 yr). A pneumatic-movement actuator was used to evoke right index-finger flexion-extension movement at 3 Hz for 4 min. The task was repeated both with the wireless-EEG and wired-EEG devices using the same 30-channel EEG cap preparation. CKC was computed between the EEG and finger acceleration. CKC peaked at the movement frequency and its harmonics, being statistically significant (p < 0.05) in 8–10 out of 11 participants. No statistically significant differences (p < 0.05) were found in CKC strength between wireless-EEG (range 0.03-0.22) and wired-EEG (0.02-0.33) systems, that showed a good agreement between the recording systems (3 Hz: r = 0.57, p = 0.071, 6 Hz: r = 0.82, p = 0.003). As expected, CKC peaked in sensors above the left primary sensorimotor cortex contralateral to the moved right index finger. As the wired-EEG device, the tested wireless-EEG system has proven feasible to quantify CKC, and thus can be used as a tool to study proprioception in the human neocortex. Thanks to its portability, the wireless-EEG used in this study has the potential to enable the examination of cortical proprioception in more naturalistic conditions outside the laboratory environment. Clinical Relevance—Our study will contribute to provide innovative technological foundations for future unobtrusive EEG recordings in naturalistic conditions to examine human sensorimotor system.
...
Julkaisija
IEEEEmojulkaisun ISBN
978-1-7281-2783-5Konferenssi
Annual International Conference of the IEEE Engineering in Medicine & Biology SocietyKuuluu julkaisuun
EMBC 2022 : 44th Annual International Conference of the IEEE Engineering in Medicine & Biology SocietyISSN Hae Julkaisufoorumista
2375-7477Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/156476963
Metadata
Näytä kaikki kuvailutiedotKokoelmat
- Liikuntatieteiden tiedekunta [3164]
Rahoittaja(t)
Suomen AkatemiaRahoitusohjelmat(t)
Akatemiatutkijan tutkimuskulut, SA; Profilointi, SALisätietoja rahoituksesta
This study was supported by the Academy of Finland (grants #296240 and #327288) to HP, Jane and Aatos Erkko Foundation (602.274) to HP, and “Brain changes across the life-span” profiling funding to Univ. of Jyväskylä (grant #311877).Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
More comprehensive proprioceptive stimulation of the hand amplifies its cortical processing
Hakonen, Maria; Nurmi, Timo; Vallinoja, Jaakko; Jaatela, Julia; Piitulainen, Harri (American Physiological Society, 2022)Corticokinematic coherence (CKC) quantifies the phase coupling between limb kinematics and cortical neurophysiological signals reflecting proprioceptive feedback to the primary sensorimotor (SM1) cortex. We studied whether ... -
Design of a programmable and modular neuromuscular electrical stimulator integrated into a wireless Body Sensor Network
Cerone, Giacinto Luigi; Giangrande, Alessandra; Vieira, Taian; Pisaturo, Domenico; Ionescu, Mihai; Gazzoni, Marco; Botter, Alberto (Institute of Electrical and Electronics Engineers (IEEE), 2021)Neuromuscular electrical stimulation finds application in several fields, from basic neurophysiology, to motor rehabilitation and cardiovascular conditioning. Despite the progressively increasing interest in this technique, ... -
LoRa-Based Sensor Node Energy Consumption with Data Compression
Väänänen, Olli; Hämäläinen, Timo (IEEE, 2021)In this paper simple temporal compression algorithms' efficiency to reduce LoRa-based sensor node energy consumption has been evaluated and measured. It is known that radio transmission is the most energy consuming operation ... -
Maintained volitional activation of the muscle alters the cortical processing of proprioceptive afference from the ankle joint
Giangrande, Alessandra; Mujunen, Toni; Luigi, Cerone Giacinto; Botter, Alberto; Piitulainen, Harri (Elsevier, 2024)Cortical proprioceptive processing of intermittent, passive movements can be assessed by extracting evoked and induced electroencephalographic (EEG) responses to somatosensory stimuli. Although the existent prior research ... -
Volitional muscle activation intensifies neuronal processing of proprioceptive afference in the primary sensorimotor cortex : an EEG study
Giangrande, Alessandra; Cerone, Giacinto Luigi; Botter, Alberto; Piitulainen, Harri (American Physiological Society, 2024)Proprioception refers to the ability to perceive the position and movement of body segments in space. The cortical aspects of the proprioceptive afference from the body can be investigated using corticokinematic coherence ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.