The reliability of measuring medial gastrocnemius muscle-tendon unit lengths during gait
Cenni, F., Schless, S.-H., Adams, H., Bar-On, L., & Desloovere, K. (2021). The reliability of measuring medial gastrocnemius muscle-tendon unit lengths during gait. Gait and Posture, 90, 464-467. https://doi.org/10.1016/j.gaitpost.2021.09.198
Julkaistu sarjassa
Gait and PosturePäivämäärä
2021Tekijänoikeudet
© 2021 The Authors. Published by Elsevier B.V.
Background
Ultrasound imaging combined with 3D motion analysis allows for in-vivo assessment of muscle-tendon unit lengths during gait. The clinical relevance of analysing the medial gastrocnemius (MG) and Achilles muscle-tendon junction (MTJ), MG mid-muscle belly fascicles (FAS) and muscle thickness was shown. However, their reliability error estimations over the gait cycle is unknown.
Research question
What are the intra- and inter-session errors associated with extracting MG belly, thickness, FAS and tendon lengths using ultrasound during gait in healthy participants?
Methods
3D gait analysis was carried out in ten healthy adults as they walked on an instrumented treadmill at a comfortable walking speed. An ultrasound probe was secured on the leg and tracked by 3D motion analysis. Images were collected during two walking trials with the probe on the MG muscle-belly to estimate FAS lengths and muscle thickness, and during two trials with the probe on the MTJ to estimate muscle-belly and tendon lengths. A second session was performed after 5 ± 4 days where a different operator placed the ultrasound probe. The standard deviation (SD) of absolute and relative lengths changes during the gait cycle over different trials were calculated per participant. SD values averaged over participants represented intra- and inter-session errors.
Results
For all assessed variables, the intra-session errors were <2.2 mm, except for the FAS lengths (3.1 mm). The inter-session errors were larger than the intra-session, with the highest values found for the absolute muscle-tendon unit lengths (5.6 mm). Relative length errors were smaller than absolute length errors.
Significance
Intra-session errors, which may reflect natural variability and data processing errors, seem more critical when extracting absolute FAS than muscle-tendon lengths. Standardized probe positioning on the MTJ between sessions may improve the inter-session reliability. Expressing the lengths relative to their lengths as the beginning of the gait cycle reduces the inter-session errors.
...
Julkaisija
Elsevier BVISSN Hae Julkaisufoorumista
0966-6362Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/101618153
Metadata
Näytä kaikki kuvailutiedotKokoelmat
- Liikuntatieteiden tiedekunta [3120]
Lisätietoja rahoituksesta
We would like to acknowledge the Promobilia Foundation, the Research Foundation Flanders and the Netherlands Organization for Scientific Research for funding. The sponsors had no role in the design and conduct of this study; collection analysis, and interpretation of data; preparation, review or approval of the manuscript; and decision to submit the manuscript for publication.Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Tendon length estimates are influenced by tracking location
Finni, Taija; Peter, Annamaria; Khair, Ra’ad; Cronin, Neil J. (Springer Science and Business Media LLC, 2022)Purpose Measurement of medial gastrocnemius (MG) tendon length using ultrasonography (US) requires the muscle–tendon junction (MTJ) to be located. Previously, the MG MTJ has been tracked from different proximo-distal ... -
Exploration of muscle–tendon biomechanics one year after Achilles tendon rupture and the compensatory role of flexor hallucis longus
Khair, Ra'ad M.; Stenroth, Lauri; Cronin, Neil J.; Ponkilainen, Ville; Reito, Aleksi; Finni, Taija (Elsevier, 2023)Achilles tendon (AT) rupture leads to long-term structural and functional impairments. Currently, the predictors of good recovery after rupture are poorly known. Thus, we aimed to explore the interconnections between ... -
Medial gastrocnemius muscle fascicle function during heel-rise after non-operative repair of Achilles tendon rupture
van Dijk, Koen; Khair, Raad M.; Sukanen, Maria; Cronin, Neil J.; Finni, Taija (Elsevier BV, 2023)Background To better understand muscle remodelling in dynamic conditions after an Achilles tendon rupture, this study examined the length of medial gastrocnemius muscle fascicles during a heel-rise at 6- and 12-months ... -
Muscle‐tendon morphology and function following long‐term exposure to repeated and strenuous mechanical loading
Bissas, Athanassios; Havenetidis, Konstantinos; Walker, Josh; Hanley, Brian; Nicholson, Gareth; Metaxas, Thomas; Christoulas, Kosmas; Cronin, Neil J. (Wiley-Blackwell, 2020)We mapped structural and functional characteristics of muscle‐tendon units in a population exposed to very long‐term routine overloading. Twenty‐eight military academy cadets (age: 21.00 ± 1.1 yrs; height: 176.1 ± 4.8 cm; ... -
Achilles Tendon Stiffness : Influence of Measurement Methodology
Khair, Ra'ad M.; Sukanen, Maria; Finni, Taija (Elsevier, 2024)Objective Mechanical stiffness derived from force-elongation curves is fundamentally different from shear wave (SW) elastography-based tissue properties. We compared these techniques, with a total of five methods of ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.