The electrocardiographic ‘triangular QRS-ST-T waveform’ pattern : a marker of severe haemodynamic compromise in Takotsubo syndrome : a case report
Abstract
Background
Takotsubo cardiomyopathy is characterized by transient regional systolic dysfunction of the left ventricle, mimicking myocardial infarction. Although systolic left ventricular (LV) function normalizes in most cases, the outcome is not always favourable. Recently, a rare electrocardiogram (ECG) finding, lambda wave ST elevation or ‘triangular QRS-ST-T waveform’, was suggested as a possible marker of poor outcome in Takotsubo patients
Case summary
After a brief episode of chest pain and shortness of breath, a 67-year-old woman developed cardiogenic shock. Her resting ECG showed widespread ST elevations, which soon evolved into a pattern of triangular QRS-ST-T waveforms in the inferior leads and V3–V6. Emergent coronary angiography was normal. The ejection fraction was 20% with apical ballooning and an LV thrombus. At 1-month follow-up, the patient was asymptomatic and the ECG showed only T-wave inversions.
Discussion
The triangular QRS-ST-T waveform ECG pattern has recently been introduced as a high-risk marker in the Takotsubo syndrome.
Main Authors
Format
Articles
Research article
Published
2020
Series
Subjects
Publication in research information system
Publisher
Oxford University Press
The permanent address of the publication
https://urn.fi/URN:NBN:fi:jyu-202004282945Käytä tätä linkitykseen.
Review status
Peer reviewed
ISSN
2514-2119
DOI
https://doi.org/10.1093/ehjcr/ytaa076
Language
English
Published in
European Heart Journal - Case Reports
Citation
- Joki, T., Nikus, K., & Laukkanen, J. (2020). The electrocardiographic ‘triangular QRS-ST-T waveform’ pattern : a marker of severe haemodynamic compromise in Takotsubo syndrome : a case report. European Heart Journal - Case Reports, 4(3), 1-6. https://doi.org/10.1093/ehjcr/ytaa076
Copyright© The Authors 2020. Published by Oxford University Press on behalf of the European Society of Cardiology