Three-dimensional analysis of tumour vascular corrosion casts using stereoimaging and micro-computed tomography
Folarin, A., Konerding, M., Timonen, J., Nagl, S., & Pedley, B. (2010). Three-dimensional analysis of tumour vascular corrosion casts using stereoimaging and micro-computed tomography. Microvascular Res., 80, 89-98. https://doi.org/10.1016/j.mvr.2010.03.007
Julkaistu sarjassa
Microvascular Res.Päivämäärä
2010Tekijänoikeudet
© 2010 Elsevier Inc
Objective
In order to perform effective translational research for cancer therapy, we need to employ pre-clinical models which reflect the clinical situation. The purpose of this study was to quantitatively compare the vascular architecture of human colorectal cancer and experimental tumour models to determine the suitability of animal models for vascular studies and antivascular therapy.
Methods
In this study we investigated the three-dimensional properties of colonic tumour vasculature in both human clinical tissues (normal mucosa control [n = 20], carcinoma [n = 20] and adenoma [n = 6]) and murine colorectal xenografts (LS147T [n = 6] and SW1222 [n = 6]). Scanning Electron Microscope Stereoimaging (SEM) and X-ray Micro-Computed Tomography (Micro-CT) methods were employed for 3D analyses of the vascular corrosion casts from these tissues.
Results
Morphological measurements showed that there were significant differences in the underlying morphology in the different tissues. Of the studied xenografts, LS147T is more consistently similar to the vascular architecture of the human carcinoma than SW1222. The only reversal of this is for the inter-vessel distance.
Conclusion
While SEM stereoimaging provided better surface detailed resolution of the corrosion casts, it was complimented by the fully 3D micro-CT method. Comparison made between the xenografts and clinical tumours showed that the LS147T xenografts shared many similarities with the clinical tumour vasculature. This study provides insight into how to select the most suitable pre-clinical models for translational studies of clinical cancer therapy.
...
ISSN Hae Julkaisufoorumista
0026-2862Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/20225121
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Characterization of three-dimensional microstructure of composite materials by X-ray tomography
Miettinen, Arttu (University of Jyväskylä, 2016)Analysis methods for X-ray microtomographic images of short fibre composite materials were developed. The methods enable estimation of microstructural properties of the material, e.g., aspect ratio and orientation of ... -
X-ray tomographic method for measuring three-dimensional deformation and water content distribution in swelling clays
Harjupatana, Tero; Alaraudanjoki, Jarno; Kataja, Markku (Elsevier BV, 2015)A non-invasive method for simultaneous measurement of the 3D displacement field and the water content distribution of a wetted solid material is developed. The method is based on comparison of X-ray tomographic images of ... -
Three-dimensional architecture of the whole human soleus muscle in vivo
Bolsterlee, Bart; Finni Juutinen, Taija; D’Souza, Arkiev; Eguchi, Junya; Clarke, Elizabeth C.; Herbert, Robert D. (PeerJ Inc., 2018)Background Most data on the architecture of the human soleus muscle have been obtained from cadaveric dissection or two-dimensional ultrasound imaging. We present the first comprehensive, quantitative study on the ... -
Groupware architecture for requirements processes in new product development
Salo, Ahti; Käkölä, Timo (IEEE, 1999)An organization's ability to create successful products depends on how extensively it collects, analyzes and utilizes requirements information in its product development. Recent advances in groupware technologies allow ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.