Towards higher sensitivity at the RITU focal plane
dc.contributor.author | Kettunen, Heikki | |
dc.contributor.author | Greenlees, Paul | |
dc.contributor.author | Helariutta, Kerttuli | |
dc.contributor.author | Jones, Peter | |
dc.contributor.author | Julin, Rauno | |
dc.contributor.author | Juutinen, Sakari | |
dc.contributor.author | Kuusiniemi, Pasi | |
dc.contributor.author | Leino, Matti | |
dc.contributor.author | Muikku, Maarit | |
dc.contributor.author | Nieminen, Päivi | |
dc.contributor.author | Uusitalo, Juha | |
dc.date.accessioned | 2019-02-19T09:52:14Z | |
dc.date.available | 2019-02-19T09:52:14Z | |
dc.date.issued | 2001 | |
dc.identifier.citation | Kettunen, H., Greenlees, P., Helariutta, K., Jones, P., Julin, R., Juutinen, S., Kuusiniemi, P., Leino, M., Muikku, M., Nieminen, P., & Uusitalo, J. (2001). Towards higher sensitivity at the RITU focal plane. <i>Acta Physica Polonica B</i>, <i>32</i>(3), 989. <a href="http://www.actaphys.uj.edu.pl/fulltext?series=Reg&vol=32&page=989" target="_blank">http://www.actaphys.uj.edu.pl/fulltext?series=Reg&vol=32&page=989</a> | |
dc.identifier.other | CONVID_26512085 | |
dc.identifier.other | TUTKAID_7279 | |
dc.identifier.uri | https://jyx.jyu.fi/handle/123456789/62859 | |
dc.description.abstract | The recently reconstructed focal plane detector system for the gas-filled recoil separator RITU was used to observe a new proton emitter 164Ir. The nuclide was produced via the p5n fusion evaporation channel using a 64Zn beam on a 106Cd target. The proton energy Ep = 1817(9) keV and half-life T1/2 = 113+62-30 μ s were used to characterize the decaying state to be [π h11/2 ν f7/2]9+. The new focal plane detector system and the results of the proton decay studies will be discussed. | fi |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.publisher | Jagellonian University | |
dc.relation.ispartofseries | Acta Physica Polonica B | |
dc.relation.uri | http://www.actaphys.uj.edu.pl/fulltext?series=Reg&vol=32&page=989 | |
dc.rights | CC BY 4.0 | |
dc.subject.other | focal planes | |
dc.subject.other | detector systems | |
dc.title | Towards higher sensitivity at the RITU focal plane | |
dc.type | article | |
dc.identifier.urn | URN:NBN:fi:jyu-201902061439 | |
dc.contributor.laitos | Fysiikan laitos | fi |
dc.contributor.laitos | Department of Physics | en |
dc.type.uri | http://purl.org/eprint/type/JournalArticle | |
dc.date.updated | 2019-02-06T10:15:22Z | |
dc.description.reviewstatus | peerReviewed | |
dc.format.pagerange | 989 | |
dc.relation.issn | 0587-4254 | |
dc.relation.numberinseries | 3 | |
dc.relation.volume | 32 | |
dc.type.version | acceptedVersion | |
dc.rights.copyright | © Authors, 2001 | |
dc.rights.accesslevel | openAccess | fi |
dc.format.content | fulltext | |
dc.rights.url | https://creativecommons.org/licenses/by/4.0/ |