Charge breeding time investigations of electron cyclotron resonance charge breeders
Angot, J., Tarvainen, O., Thuillier, T., Baylac, M., Lamy, T., Sole, P., & Jacob, J. (2018). Charge breeding time investigations of electron cyclotron resonance charge breeders. Physical Review Accelerators and Beams, 21(10), Article 104801. https://doi.org/10.1103/physrevaccelbeams.21.104801
Julkaistu sarjassa
Physical Review Accelerators and BeamsTekijät
Päivämäärä
2018Tekijänoikeudet
© Authors, 2018
To qualify electron cyclotron resonance charge breeders, the method that is traditionally used to evaluate the charge breeding time consists in generating a rising edge of the injected beam current and measuring the time in which the extracted multicharged ion beam reaches 90% of its final current. It is demonstrated in the present paper that charge breeding times can be more accurately measured by injecting short pulses of
1
+
ions
and recording the time resolved responses of
N
+
ions. This method is used to probe the effect of the
1
+
ion
accumulation in the plasma known to disturb the buffer gas plasma equilibrium and is a step further in understanding the large discrepancies reported in charge breeding times. The experiments are conducted injecting a
85
Rb
+
ion beam into the Laboratoire de Physique Subatomique et de Cosmologie (LPSC) charge breeder operated with helium as a buffer gas. The time needed for the extraction of 90% of the multicharged ions in short pulse mode is found slightly shorter (9%) than the charge breeding time measured with the traditional method. The charge breeding efficiency is identical with both methods. The pulse width and amplitude of the
1
+
injection pulses have been varied to study their influence on the
N
+
response and temporal parameters are proposed to qualify the time response. The short pulse method can be used to study the influence of the ion source tuning parameters on the charge breeding temporal characteristics. For example, it is shown here that an increase of the minimum magnetic field strength of the LPSC charge breeder in the range 0.432–0.444 T improves the multicharged ion confinement in the electron cyclotron resonance plasma, and so increases the charge breeding efficiency. The short pulse method is also used to estimate the charge breeding efficiencies of radioactive Rb isotopes taking into account their half-lives and charge states. The neutron-rich heavy isotopes have short half-lives, which makes the charge state distributions shift to lower charge states and the estimated charge breeding efficiencies of high charge states being close to three times less in comparison to the stable ions.
...
Julkaisija
American Physical SocietyISSN Hae Julkaisufoorumista
2469-9888Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/28699917
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Bremsstrahlung Emission of an X-Band Permanent Magnet Minimum-B Quadrupole Electron Cyclotron Resonance Ion Source
Tarvainen, Olli; Toivanen, Ville; Kalvas, Taneli; Koivisto, Hannu A.; Kosonen, Sami (Institute of Electrical and Electronics Engineers (IEEE), 2024)We have carried out bremsstrahlung measurements on a permanent magnet minimum-B quadrupole electron cyclotron resonance (ECR) ion source operating at 10.3–11.5 GHz microwave frequencies. The bremsstrahlung spectral temperature ... -
Asymptotic and numerical studies of electron scattering in 2D quantum waveguides of variable cross-section
Kabardov, Muaed (University of Jyväskylä, 2012) -
Measurement of the energy distribution of electrons escaping minimum-B ECR plasmas
Izotov, Ivan; Tarvainen, Olli; Skalyga, Vadim; Mansfeld, Dmitry; Kalvas, Taneli; Koivisto, Hannu; Kronholm, Risto (IOP Publishing, 2018)The measurement of the electron energy distribution (EED) of electrons escaping axially from a minimum-B electron cyclotron resonance ion source (ECRIS) is reported. The experimental data were recorded with a room-temperature ... -
The biased disc of an electron cyclotron resonance ion source as a probe of instability-induced electron and ion losses
Tarvainen, O.; Kronholm, R.; Kalvas, T.; Koivisto, H.; Izotov, I.; Skalyga, V.; Toivanen, V.; Maunoury, L. (American Institute of Physics, 2019)Electron Cyclotron Resonance Ion Source (ECRIS) plasmas are prone to kinetic instabilities resulting in loss of electron and ion confinement. It is demonstrated that the biased disk of an ECRIS can be used as a probe to ... -
The effects of electron energy distribution and ionization cross section uncertainty on charge breeder ion source diagnostics with pulsed 1+ injection
Luntinen, M.; Angot, J.; Koivisto, H.; Tarvainen, O.; Thuillier, T.; Toivanen, V. (AIP Publishing, 2023)The consecutive transients (CT) method is a plasma diagnostic technique of charge breeder electron cyclotron resonance ion source plasmas. It is based on the short-pulse injection of singly charged ions and the measurement ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.