Näytä suppeat kuvailutiedot

dc.contributor.authorLehtimäki, Esa
dc.contributor.authorVäisänen, Ari
dc.date.accessioned2016-12-20T07:51:59Z
dc.date.available2018-12-02T22:35:30Z
dc.date.issued2017
dc.identifier.citationLehtimäki, E., & Väisänen, A. (2017). Determination of metal concentrations in certified plastic reference materials after small-size autoclave and microwave-assisted digestion followed with inductively coupled plasma optical emission spectrometry. <i>Spectrochimica Acta Part B: Atomic Spectroscopy</i>, <i>127</i>, 64-69. <a href="https://doi.org/10.1016/j.sab.2016.11.011" target="_blank">https://doi.org/10.1016/j.sab.2016.11.011</a>
dc.identifier.otherCONVID_26357139
dc.identifier.otherTUTKAID_71944
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/52465
dc.description.abstractThe digestion methods for the determination of As, Cd, Cr, Pb, Sb, Sn and Zn concentrations in plastic samples using microwave-assisted digestion (MW-AD) and small-size autoclave digestion was developed. The certified polyethylene, polypropylene, polyvinyl chloride and acrylonitrile butadiene styrene certified reference materials were used in order to find digestion method working properly for several sample matrices. Efficiency of the digestion methods was evaluated by analyzing the residual carbon in digests by TOC analyzer. MW-AD using a mixture of 7 mL of HNO3 and 3 mL of H2O2 as a digestion solution resulted in excellent recoveries for As, Cd, Pb, Sb and Zn, and were in the range of 92–107% for all the analytes except Pb in polyethylene material. Autoclave digestion using 5 mL of concentrated HNO3 as a digestion solution resulted in similar recoveries with the exception of a higher As recovery (98%). Tin recovery resulted in low level after both MW-AD and autoclave digestion. Autoclave digestion was further developed resulting in a partially open two-step digestion process especially for the determination of Sn and Cr. The method resulted in higher recoveries of Sn and Cr (87 and 76%) but with the lower concentration of easily volatile As, Cd and Sb.
dc.language.isoeng
dc.publisherElsevier BV
dc.relation.ispartofseriesSpectrochimica Acta Part B: Atomic Spectroscopy
dc.subject.otherICP-OES
dc.subject.otherautoclave
dc.subject.othermicrowave
dc.subject.otherdetermination
dc.titleDetermination of metal concentrations in certified plastic reference materials after small-size autoclave and microwave-assisted digestion followed with inductively coupled plasma optical emission spectrometry
dc.typearticle
dc.identifier.urnURN:NBN:fi:jyu-201612205178
dc.contributor.laitosKemian laitosfi
dc.contributor.laitosDepartment of Chemistryen
dc.contributor.oppiaineEpäorgaaninen ja analyyttinen kemiafi
dc.contributor.oppiaineInorganic and Analytical Chemistryen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.date.updated2016-12-20T04:15:05Z
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.format.pagerange64-69
dc.relation.issn0584-8547
dc.relation.numberinseries0
dc.relation.volume127
dc.type.versionacceptedVersion
dc.rights.copyright© 2016 Elsevier B.V. This is a final draft version of an article whose final and definitive form has been published by Elsevier. Published in this repository with the kind permission of the publisher.
dc.rights.accesslevelopenAccessfi
dc.subject.ysoruoansulatus
dc.subject.ysomuovi
jyx.subject.urihttp://www.yso.fi/onto/yso/p12121
jyx.subject.urihttp://www.yso.fi/onto/yso/p924
dc.relation.doi10.1016/j.sab.2016.11.011
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot