Show simple item record

dc.contributor.authorPartanen, Vesa
dc.date.accessioned2011-10-13T17:28:20Z
dc.date.available2011-10-13T17:28:20Z
dc.date.issued2011
dc.identifier.otheroai:jykdok.linneanet.fi:1185384
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/36806
dc.description.abstractIn an experimental nuclear physics off-line systems are often used in situations where acceleration energies are relatively small. Main benefits are low price and meager radiated laboratory enviroments. In this master’s thesis I discuss mostly about automation which was used in our off-line system. The system was built at the Ion Guide Separator On-Line facility (IGISOL) in Jyväskylä University. The automation set up was made with the Phoenix Contacts inline terminals, which were programmed by using the Labview program. The system consists of thermistor, skimmer handling, mirror handling, gasline parts per billion (ppb) mixing and quadrupole mass spectrometer measurement. There were major problems with the control unit of the quadrupole mass spectrometer, hence this project is truly unfinished. On the other hand, the system will be modified for various purposes, so the system was partly tested. Test results show that the system works with low mass-charge particles. I have included quite detailed descriptions about my programs, thus this thesis can be also used as a program manual.
dc.format.extent173 sivua
dc.format.mimetypeapplication/pdf
dc.language.isofin
dc.rightsThis publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.en
dc.rightsJulkaisu on tekijänoikeussäännösten alainen. Teosta voi lukea ja tulostaa henkilökohtaista käyttöä varten. Käyttö kaupallisiin tarkoituksiin on kielletty.fi
dc.subject.otheroff-line
dc.subject.otherexperimental nuclear physics
dc.subject.otherkokeellinen ydinfysiikka
dc.subject.otherautomation
dc.subject.otherautomaatio
dc.subject.otherLabview
dc.subject.otherquadrupole mass spectrometer
dc.subject.otherkvadrupolimassaspektrometri
dc.subject.otherlaser-ionization
dc.subject.otherlaser-ionisaatio
dc.subject.othervacuum
dc.subject.othertyhjiö
dc.subject.othergas impurity
dc.subject.otherepäpuhtaudet
dc.titleKompakti automatisoitu laser-ionisointijärjestelmä
dc.identifier.urnURN:NBN:fi:jyu-2011101311542
dc.type.dcmitypeTexten
dc.type.ontasotPro gradu -tutkielmafi
dc.type.ontasotMaster’s thesisen
dc.contributor.tiedekuntaMatemaattis-luonnontieteellinen tiedekuntafi
dc.contributor.tiedekuntaFaculty of Sciencesen
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.contributor.yliopistoUniversity of Jyväskyläen
dc.contributor.yliopistoJyväskylän yliopistofi
dc.contributor.oppiaineFysiikkafi
dc.contributor.oppiainePhysicsen
dc.date.updated2011-10-13T17:28:21Z
dc.rights.accesslevelopenAccessfi
dc.type.publicationmasterThesis
dc.contributor.oppiainekoodi4021
dc.subject.ysoydinfysiikka
dc.subject.ysoautomaatio
dc.subject.ysoepäpuhtaudet
dc.subject.ysolasertekniikka
dc.format.contentfulltext
dc.type.okmG2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record