Penning trap for isobaric purification of radioactive ion beams at IGISOL
Julkaistu sarjassa
Research report / Department of Physics, University of JyväskyläTekijät
Päivämäärä
2003Oppiaine
FysiikkaJulkaisija
University of JyväskyläISBN
978-951-39-3141-4ISSN Hae Julkaisufoorumista
0075-465XMetadata
Näytä kaikki kuvailutiedotKokoelmat
- Väitöskirjat [3411]
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Radioactive ion beam manipulation at the IGISOL-4 facility
Penttilä, Heikki; Beliuskina, Olga; Canete, Laetitia; de Roubin, Antoine; Eronen, Tommi; Hukkanen, Marjut; Kankainen, Anu; Moore, Iain; Nesterenko, Dmitrii; Papadakis, Philippos; Pohjalainen, Ilkka; Reponen, Mikael; Rinta-Antila, Sami; Sarén, Jan; Uusitalo, Juha; Vilén, Markus; Virtanen, Ville (EDP Sciences, 2020)The IGISOL-4 facility in the JYFL Accelerator Laboratory of the University of Jyvaskyla (JYFL-ACCLAB) produces low-energy radioactive ion beams, primarily for nuclear spectroscopy, utilizing an ion guide-based, ISOL-type ... -
High-precision mass measurements for the isobaric multiplet mass equation at A = 52
Nesterenko, Dmitrii; Kankainen, Anu; Canete, Laetitia; Block, M.; Cox, Daniel; Eronen, Tommi; Fahlander, C.; Forsberg, U.; Gerl, J.; Golubev, P.; Hakala, Jani; Jokinen, Ari; Kolhinen, Veli; Koponen, Jukka; Lalović, N.; Lorenz, Ch.; Moore, Iain; Papadakis, Philippos; Reinikainen, Juuso; Rinta-Antila, Sami; Rudolph, D.; Sarmiento, L. G.; Voss, Annika; Äystö, Juha (IOP Publishing Ltd, 2017)Masses of 52Co, 52Com, 52Fe, 52Fem, and 52Mn have been measured with the JYFLTRAP double Penning trap mass spectrometer. The isobaric multiplet mass equation for the T = 2 quintet at A = 52 has been studied employing the ... -
Breakdown of the isobaric multiplet mass equation (IMME) at A=33, T=3/2
Herfurth, F.; Dilling, J.; Kellerbauer, A.; Audi, G.; Beck, D.; Bollen, G.; Kluge, H.-J.; Lunney, D.; Moore, R. B.; Scheidenberger, C.; Schwarz, S.; Sikler, G.; Szerypo, Jerzy; Collaboration, ISOLDE (American Physical Society, 2001)Mass measurements on 3 3 , 3 4 , 4 2 , 4 3 Ar were performed using the Penning trap mass spectrometer ISOLTRAP and a newly constructed linear Paul trap. This arrangement allowed us, for the first time, to ... -
Mass of astrophysically relevant 31Cl and the breakdown of the isobaric multiplet mass equation
Kankainen, Anu; Canete, Laetitia; Eronen, Tommi; Hakala, Jani; Jokinen, Ari; Koponen, Jukka; Moore, Iain; Nesterenko, Dmitrii; Reinikainen, Juuso; Rinta-Antila, Sami; Voss, Annika; Äystö, Juha (American Physical Society, 2016)The mass of 31Cl has been measured with the JYFLTRAP double-Penning-trap mass spectrometer at the Ion Guide Isotope Separator On-Line (IGISOL) facility. The determined mass-excess value, −7034.7(34) keV, is 15 times more ... -
JYFLTRAP: a Penning trap for precision mass spectroscopy and isobaric purification
Eronen, Tommi; Kolhinen, Veli; Elomaa, Viki-Veikko; Gorelov, Dmitry; Hager, Ulrike; Hakala, Jani; Jokinen, Ari; Kankainen, Anu; Karvonen, Pasi; Kopecky, Stefan; Moore, Iain; Penttilä, Heikki; Rahaman, Saidur; Rinta-Antila, Sami; Rissanen, Juho; Saastamoinen, Antti; Szerypo, Jerzy; Weber, Christine; Äystö, Juha (Springer, 2012)In this article a comprehensive description and performance of the double Penning-trap setup JYFLTRAP will be detailed. The setup is designed for atomic mass measurements of both radioactive and stable ions and additionally ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.